Skip to content
ASUNLaboratory
Insights

Edible oils

Reading a Certificate of Analysis for sunflower oil

FFA, peroxide value, M&I, iodine value — what each number on an edible-oil CoA means and which ones move the price.

ASUN Oils & Fats Laboratory·9 October 2026·8 min read

Refined sunflower oil is one of the most traded edible oils in the world, and most contracts specify it on a short list of parameters. Understanding them helps buyers spot problems before they become claims.

Free fatty acids (FFA)

FFA measures how much of the oil has hydrolysed into free acids. For RBD sunflower oil a typical maximum is 0.1% as oleic acid; for crude oil, contracts commonly allow up to 1.5–2.0%. Crude oil with high FFA costs more to refine because the refinery loses more oil in neutralisation.

Peroxide value (PV)

Peroxide value measures primary oxidation. Fresh refined oil usually shows below 2 meq O₂/kg, and a common contract maximum is 10. A rising PV during storage tells you the oil is oxidising — often due to heat, light or air exposure in tanks.

Moisture and impurities (M&I)

Water and insoluble solids are paid for at the price of oil unless they are measured. Typical limits are 0.1% for refined and 0.2–0.5% for crude oil. High moisture also accelerates hydrolysis, so M&I and FFA tend to rise together.

Iodine value and fatty acid composition

Iodine value indicates the degree of unsaturation. Standard sunflower oil sits around 118–141 g I₂/100 g, while high-oleic sunflower oil is much lower. The fatty-acid profile by gas chromatography is the best authenticity check: linoleic acid should dominate in standard sunflower oil, and unexpected palmitic or linolenic acid levels suggest blending.

Colour

Colour is measured on the Lovibond scale in a 5¼-inch cell. Refined sunflower oil is usually specified at red ≤ 1.5 to 2.0. Colour is an indicator of refining and bleaching quality.

ParameterTypical RBD specMethod
FFA (as oleic)≤ 0.10 %ISO 660
Peroxide value≤ 10 meq/kgISO 3960
Moisture & impurities≤ 0.10 %ISO 662 / 663
Iodine value118–141ISO 3961
Colour (Lovibond 5¼")≤ 2.0 RAOCS Cc 13e-92

What ASUN adds

A good CoA states the sampling point (shore tank, ship's composite, flexitank), the date of sampling and the methods used. Our certificates show all three, and every result can be checked online against our register.

Keep reading

Next shipment

Nominate ASUN in your contract.
Load with certainty.

Send us the commodity, specification, load port and dates. A local coordinator confirms scope, methods and fees within one business day.